view cart | download catalog | contact us

PRODUCTS

Vortex Mixers
VORTEX MIXERS

Pulsing Vortex Mixer
PULSING VORTEX MIXER

Large Capacity Vortex Mixers
LARGE CAPACITY SHAKERS

Microplate Mixers/Shakers
MICROPLATE MIXERS/SHAKERS

Orbital Shakers
ORBITAL SHAKERS

Magnetic Stirrers
MAGNETIC STIRRERS

Refrigerated Incubators
REFRIGERATED INCUBATOR

Shaking Incubators
SHAKING
INCUBATOR

Rotators/Rockers
ROTATORS/
ROCKERS

Disruptors/Homogenizers
DISRUPTORS/ HOMOGENIZERS

MicroPlate & Multi-MicroPlate Genie Applications

 

Highly sensitive microplate ß-galactosidase assay for yeast two-hybrid systems

Brouchon-Macari, L., Joseph, M., Dagher, M. Highly sensitive microplate ß-galactosidase assay for yeast two-hybrid systems. BioTechniques Vol. 35, No. 3, 446-448 (2003).

“Culture for 20 h with shaking in a deep-well, conical-bottom microplate.” (Yeast Culture protocol)

“Shake at 800 rpm for 10 min at 30°C.” (ß-Galactosidase Assay)

« return to applications page

« return to MicroPlate Genie product page or Multi-MicroPlate Genie product page


Localized transfection on arrays of magnetic beads coated with PCR products

Isalan, M., Santori, M., Gonzalez, C., Serrano, L. Localized transfection on arrays of magnetic beads coated with PCR products. Nature MethodsVol. 2, No. 2,113-118 (2005).

“We pipetted 10 µl bead aliquots in a 96-well plate, adding 5 µl of water plus 5 µl of PCR product per well. After mixtures were incubated for 3 h at 22 °C, with mixing at 800 r.p.m, ...”

“We incubated the plate for 45 min at 22 °C with mixing at 800 r.p.m ...”

« return to applications page

« return to MicroPlate Genie product page or Multi-MicroPlate Genie product page


Microplate Nitrate Test Kit — Standard Range

Microplate Nitrate Test Kit — Standard Range, The Nitrate Elimination Co., Inc., Lake Linden, Michigan.

“Pipet 90 µl NaR-Assay Buffer-NADH solution (prepared in Step 8 of Reagent Preparation) to each well. Shake on a plate mixer for ~20 minutes at 800 rpm.”

“Add 50 µl Color Reagent No. 1 and 50 µl Color Reagent No. 2 solution to each well. Shake on a plate mixer for ~10 minutes at 800 rpm.”

« return to applications page

« return to MicroPlate Genie product page or Multi-MicroPlate Genie product page


Scalable high-throughput micro-expression device for recombinant proteins

Page, R. et al. Scalable high-throughput micro-expression device for recombinant proteins. BioTechniques Vol. 37, No. 3, 364-370 (2004).

“[sterile 2-mL, 96-deep-well, round-bottom blocks are] grown at 900 rpm and 37°C.”

“...cultures are allowed to shake at 900 rpm and 37°C for an additional 4-5 h.”

« return to applications page

« return to MicroPlate Genie product page or Multi-MicroPlate Genie product page

 


Click Here to Browse Online Catalog

 

FREE PROMOTIONS

Free! Standard Shipping